E0300
Property | Specification |
Data System | MDS |
Data Specs | V1.15.0 |
Description | Overall presence of behavioral symptoms |
Group | Asmt |
Type | Code |
Length | 1 |
Fixed Start-End | 594-594 |
Version Notes |
Item Subsets | |
Active | NC |
Inactive | NS,NSD,NO,NOD,ND,NT,SP,SS,SSD,SO,SOD,SD,ST,XX |
State optional | NQ,NP |
Item Values | ||
Value | LOINC | Text |
0 | No | |
1 | Yes | |
- | Not assessed/no information | |
^ | Blank (skip pattern) |
Item Edits | |||
Edit ID | Type | Severity | Edit Text |
-3676 | Format | Fatal |
Values of Code and Checklist Items: Only the coded values listed in the "Item Values" table of the Detailed Data Specifications Report may be submitted for this item. |
-3675 | Consistency | Fatal |
a) If E0200A or E0200B or E0200C is equal to [1,2,3], then if E0300 is active it must be equal to [1]. b) If E0200A and E0200B and E0200C are all equal to [0], then if E0300 is active it must be equal to [0]. c) If E0200A, E0200B or E0200C is equal to [-] and the remaining two items are equal to [0,-], then if E0300 is active it must be equal to [0,-]. |
-3609 | Skip pattern | Fatal | If B0100=[1], then all active items from B0200 through F0800Z must equal [^]. |
-3523 | Skip pattern | Fatal |
a) If B0100=[0], then all active items from E0100A through E0300 must not equal [^]. b) If B0100=[-], then all active items from E0100A through E0300 must equal [-]. |
-3531 | Skip pattern | Fatal |
a) If E0300=[0,^], then all active items from E0500A through E0600C must equal [^]. b) If E0300=[1], then all active items from E0500A through E0600C must not equal [^]. c) If E0300=[-], then all active items from E0500A through E0600C must equal [-]. |
NOTICE: These materials are in the public domain and cannot be copyrighted.
Generated: 03/11/2015 04:34:37 PM