Description Unstageable - deep tissue: number at admit/reentry
Group Asmt
Type Number
Length 1
Fixed Start-End 919-919
Version Notes

Item Subsets
Active NC,NQ,NP,NSD,NOD,ND,SP,SSD,SOD,SD
Inactive NS,NO,NT,SS,SO,ST,XX
State optional

Item Values
Value LOINC Text
0 Minimum value
9 Maximum value
- Not assessed/no information
^ Blank (skip pattern)

Item Edits
Edit ID Type Severity Edit Text
-3679 Format Fatal Values of Numeric Items:
Only the values listed in the "Item Values" table of the Detailed Data Specifications Report may be submitted for this item. The submitted value must be greater than or equal to the minimum value listed in the table and less than or equal to the maximum value listed in the table, or it must match one of the remaining special values (if any) that are listed in the table. The length of the submitted value must not exceed the allowed maximum length for the item. Signed numbers (with a leading plus or minus sign) will not be accepted.
-3680 Format Fatal Formatting of Integer Numeric Items:
Only integer values and the special values (if any) that are listed in the "Item Values" table of the Detailed Data Specifications Report will be accepted for this item. Leading zeroes may be included or omitted from the submitted value as long as the resulting length of the string does not exceed the allowed maximum length for the item. A decimal point and decimal values may not be included.

The following examples are allowable if the value to be submitted is equal to [1] and the maximum length is equal to 2: [1], [01]. The following values are NOT allowed and will lead to a fatal error: [1.], [1.0], [01.], [01.0], [1.1], [01.1], [1.01].
-3667 Consistency Fatal If M0300G1 is equal to [1-9], then one of the following must be true:
a) M0300G2 must be equal to [-], OR
b) M0300G2 must be equal to [0-9] and must be less than or equal to M0300G1.
-3612 Consistency Fatal a) If M0210=[0], then all active items from M0300A through M0800C must equal [^].
b) If M0210=[-], then all active items from M0300A through M0300G2 must equal [-].
-3553 Skip pattern Fatal a) If M0300G1=[1-9], then if M0300G2 is active it must not equal [^].
b) If M0300G1=[0,^], then if M0300G2 is active it must equal [^].
c) If M0300G1=[-], then if M0300G2 is active it must equal [-].