Property | Specification |
Data System | MDS |
Data Specs | V2.00.1 |
Edit Type | None of above |
Severity | Fatal |
Edit Text |
If H0100A through H0100D and H0100Z are all active, then the following rules apply: a) If H0100Z=[0], then at least one item from H0100A through H0100D must equal [1]. b) If H0100Z=[1], then all items from H0100A through H0100D must equal [0]. c) If H0100Z=[-], then at least one item from H0100A through H0100D must equal [-] and all remaining items must equal [0,-]. |
Version Notes |
Item List | |
Item ID | Description |
H0100A | Appliances: indwelling catheter |
H0100B | Appliances: external catheter |
H0100C | Appliances: ostomy |
H0100D | Appliances: intermittent catheterization |
H0100Z | Appliances: none of the above |
NOTICE: These materials are in the public domain and cannot be copyrighted.