A0310H


Item Summary

Previous item

Next item


Property Specification
Data System MDS
Data Specs V2.00.1
Description SNF PPS Part A Discharge (End of Stay) Assessment
Group Asmt
Type Code
Length 1
Fixed Start-End 1493-1493
Version Notes [V2.00.0]-New item.

Item Subsets
Active NC,NQ,NP,NS,NSD,NO,NOD,ND,NT,SP,SS,SSD,SO,SOD,SD,ST,NPE
Inactive XX
State optional

Item Values
Value LOINC Text
0 No
1 Yes

Item Edits
Edit ID Type Severity Edit Text
-3676 Format Fatal Values of Code and Checklist Items:
Only the coded values listed in the "Item Values" table of the Detailed Data Specifications Report may be submitted for this item.
-3607 Consistency Fatal The Item Subset Code (ISC) is a two- or three-character code that indicates the type of record that is being submitted. The set of active items is controlled by the ISC. The characters of the ISC are defined as follows:

Character 1 indicates the type of provider and is based upon the value of A0200, as follows:
a) If A0200 is equal to [1] (nursing home record), then character 1 of the ISC is equal to [N].
b) If A0200 is equal to [2] (swing bed record), then character 1 of the ISC is equal to [S].

Characters 2 and 3 indicate the type of record and are based upon the values of the Reason For Assessment (RFA) items A0310A, A0310B, A0310C, A0310D, A0310F, and A0310H. The "Item Subset Code (ISC) Report" that accompanies the data specs lists all possible combinations of the RFA items and their associated ISCs. If the ISC that is listed in the report is equal to dashes, then the combination of RFA items is not allowed. If a record is submitted with one of these invalid RFA combinations, a fatal error will occur and it will be rejected.

The ISC_VAL table that is contained in the data specifications Access database is used to generate the ISC report and can be used by programmers as a lookup table. In addition, an appendix of the overview document that accompanies these data specifications contains source code for a Visual Basic function (GetISC_10012016()) that can be used to determine the ISC that is associated with any combination of the RFA items.

For a more complete explanation of the meaning and use of the ISC codes, please refer to the documentation that accompanies these data specifications.
-3875 Consistency Fatal If A0310H=[1], then A2400C must not equal [--------,^].
-3876 Consistency Fatal Date restrictions when combining SNF PPS Part A Discharge assessments with other assessment types:

(a) If A0200=[1] and (A0310A=[01,02,03,04,05,06] or A0310B=[01,02,03,04,05]) and A0310F=[99] and A0310H=[1], then A2300 must be equal to A2400C.

(b) If A0200=[2] and A0310B=[01,02,03,04,05] and A0310F=[99] and A0310H=[1], then A2300 must be equal to A2400C.

(c) If A0310F=[10,11] and A0310H=[1], then ((A2400C = A2000) OR (A2000 - A2400C = 1)).
-3877 Consistency Fatal IF (A0310F = 10 or 11) AND
((A2400C = A2000) OR (A2000 - A2400C = 1)) THEN
A0310H must be equal to 1.
-3872 Skip pattern Fatal a) If A0310G=[1,^] and A0310H=[1] and A2400C - A2400B is greater than 2 and A2100=[01,02,04,05,06,07,08,09,99,^], then GG0130A3, GG0130B3, and GG0130C3 must not be equal to [^].

b) If A0310G=[2] or A0310H=[0] or A2400C - A2400B is less than or equal to 2 or A2100=[03], then GG0130A3, GG0130B3, and GG0130C3 must be equal to [^].
-3874 Skip pattern Fatal a) If A0310G=[1,^] and A0310H=[1] and A2400C - A2400B is greater than 2 and A2100=[01,02,04,05,06,07,08,09,99,^], then the following items must not be equal to [^]: GG0170B3, GG0170C3, GG0170D3, GG0170E3, GG0170F3, GG0170H3, GG0170Q3.

b) If A0310G=[2] or A0310H=[0] or A2400C - A2400B is less than or equal to 2 or A2100=[03], then the following items must be equal to [^]: GG0170B3, GG0170C3, GG0170D3, GG0170E3, GG0170F3, GG0170H3, GG0170J3, GG0170K3, GG0170Q3, GG0170R3, GG0170RR3, GG0170S3, GG0170SS3.